Discharge Line
DESCRIPTION
The A/C discharge line is the refrigerant line that goes from the A/C compressor to the A/C condenser. The A/C discharge line is made from light-weight aluminum tubing with braze-less and crimp type fittings and nylon tubes with rubber barrier hose Description.
The A/C discharge line has an integral fitting for the A/C pressure transducer.
NOTE: Replacement of the refrigerant line O-ring seals is required anytime a refrigerant line is disconnected. Failure to replace the rubber O-ring seals may result in a refrigerant system leak.
The A/C discharge line has no serviceable parts except the O-ring seals. The O-ring seals used on the connections are made from a special type of rubber not affected by R-134a refrigerant. The O-ring seals must be replaced whenever the A/C discharge line is disconnected.
The A/C discharge line cannot be repaired and must be replaced if leaking or damaged.