ORC Accelerometer 1
ORC ACCELEROMETER 1
Theory of Operation
When powered, the Occupant Restraint Controller (ORC) performs an internal self test. The repair of this fault condition does not involve any external circuitry and centers on verifying the integrity of the module's internal circuitry and software validity.
- When Monitored:
With the ignition on.
- Set Condition:
The Occupant Restraint Controller (ORC) on board diagnostics continuously performs internal circuit tests. The ORC will set this DTC if an out of range internal circuit is identified.
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Restraints System Pre-Diagnostic Procedure
Diagnostic Test
1. REPLACE THE ORC
NOTE: Ensure that the battery is fully charged.
NOTE: Do not erase the DTCs.
Repair
WARNING: If the Occupant Restraint Controller (ORC) is dropped at any time, it must be replaced. Failure to take proper precautions could result in accidental airbag deployment and serious or fatal injury.
WARNING: To avoid serious or fatal injury, turn the ignition off, disconnect the battery and wait two minutes before proceeding.
- Replace the ORC.
- Perform *RESTRAINTS SYSTEM VERIFICATION TEST. Verification Tests