Power Locks: 46
46-LIFTGATE RELEASE SWITCH STUCK - COUPE ONLY
For a complete wiring diagram Consult Diagrams/Electrical.
- When Monitored:
Whenever the module is awake.
- Set Condition:
When the (G25) Liftgate Release Switch Sense circuit is shorted low for over 10 seconds.
Diagnostic Test
1. TEST FOR INTERMITTENT CONDITION
With the scan tool, record and erase DTC's
Operate the Liftgate Switch several times.
Turn the ignition on and wait 30 seconds.
With the scan tool, read DTC's.
Does the scan tool display 46-LIFTGATE RELEASE SWITCH STUCK?
Yes
- Go To 2
No
- The conditions that caused this code to set are not present at this time. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
2. TRUNK SWITCH SHORTED
Disconnect the Liftgate Release Switch connector.
With the scan tool, record and erase DTC's
Cycle the ignition from on to off.
Turn the ignition on.
With the scan tool, read DTC's.
Does the scan tool display 46-LIFTGATE RELEASE SWITCH STUCK?
No
- Replace the liftgate switch.
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
Yes
- Go To 3
3. (P25) LIFTGATE RELEASE SWITCH SENSE CIRCUIT SHORT TO GROUND.
Turn the ignition off.
Disconnect the Body Control Module C3 connector.
Measure the resistance between Ground and the (G25) Liftgate Release Switch sense circuit.
Is the resistance below 10,000.0 ohms?
Yes
- Repair the (G25) Liftgate Release Switch Sense circuit for a short to ground.
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
No
- Replace the Body Control Module.
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test