ABS Lamp Circuit Open
ABS LAMP CIRCUIT OPEN
For a complete wiring diagram Consult Diagrams/Electrical
- When Monitored:
The Instrument Cluster performs an indicator check each time the CAB commands the indicator On or Off.
- Set Condition:
The Instrument Cluster detects an open in the ABS lamp driver circuit (cluster internal).
Diagnostic Test
1. INSTRUMENT CLUSTER
This is an internal Instrument Cluster failure.
View repair.
- Replace the Instrument Cluster.
- Perform BODY VERIFICATION TEST - VER 1.Body Verification Test