Thermo Bypass Valve - Installation






INSTALLATION










1. Position thermal bypass valve. Install mounting bolt. Tighten mounting bolt to: 50 Nm (37 ft. lbs.).
2. Install rear transmission cooler lines to thermal bypass valve. Tighten fittings to 20 Nm (18 ft. lbs.).
3. Install front transmission cooler lines to thermal bypass valve. Tighten fittings to 20 Nm (18 ft. lbs.).