Manifold Pressure/Vacuum Sensor: Service and Repair

REMOVAL




1. Sensor location.
2. Disconnect negative battery cable.




3. Unlock the electrical connector.




4. Disconnect the electrical connector.




5. Rotate sensor 1/4 turn clockwise.
6. Pull up on sensor.




7. Remove sensor.

INSTALLATION




1. Clean MAP sensor mounting hole at intake manifold.
2. Check MAP sensor O-ring seal for cuts or tears.




3. Position sensor into intake manifold.




4. Rotate sensor 1/4 turn clockwise for installation.




5. Connect electrical connector to sensor.
6. Lock electrical connector.
7. Connect negative battery cable.