GENERATOR

REMOVAL
1. Disconnect negative battery cable.




2. Remove generator drive belt.
3. Disconnect generator field circuit plug.
4. Remove B+ terminal nut and wire.




5. Remove 2 lower mounting bolts.




6. Remove upper bolt.




7. Remove generator.

INSTALLATION




1. Install generator.




2. Install upper bolt mounting bolt.




3. Install 2 lower mounting bolts.
4. Tighten bolts to 65 N.m (48 ft. lbs.).




5. Install B+ terminal nut and wire. Tighten nut to 13 N.m (115 in. lbs.).
6. Connect generator field circuit plug.
7. Install generator drive belt.
8. Connect negative battery cable.