Alternator: Service and Repair
GENERATORREMOVAL
1. Disconnect negative battery cable.
2. Remove generator drive belt.
3. Disconnect generator field circuit plug.
4. Remove B+ terminal nut and wire.
5. Remove 2 lower mounting bolts.
6. Remove upper bolt.
7. Remove generator.
INSTALLATION
1. Install generator.
2. Install upper bolt mounting bolt.
3. Install 2 lower mounting bolts.
4. Tighten bolts to 65 N.m (48 ft. lbs.).
5. Install B+ terminal nut and wire. Tighten nut to 13 N.m (115 in. lbs.).
6. Connect generator field circuit plug.
7. Install generator drive belt.
8. Connect negative battery cable.