Cylinder Head Assembly: Testing and Inspection
INSPECTION(1) Before cleaning, check for leaks, damage and cracks.
(2) Clean cylinder head and oil passages.
Fig. 105
(3) Check cylinder head for flatness (Fig. 105).
(4) Inspect all surfaces with a straightedge if there is any reason to suspect leakage. If out-of-flatness exceeds 0.019 mm (0.00075 inch) times the span length in inches in any direction, either replace head or lightly machine the head surface. As an example, if a 12.0 inch span is 1.0 min (0.004 inch) out-of-flat, allowable is 12 x 0.019 mm (0.00075 inch) equals 0.22 min (0.009 inch. This amount of out-of-flat is acceptable. *Maximum of 0.2 mm (0.008 inch) for grinding is permitted.
CAUTION: This is a combined total dimension of stock removal from cylinder head surface.