Variable Induction Control Valve: Service and Repair
Fig 54 Retaining Clip:
REMOVAL
1. Disconnect negative battery cable.
2. Disconnect electrical connector (Fig. 53).
3. Remove manifold tuning valve mounting screws. Remove tuning valve.
INSTALLATION
1. Install tuning valve.
- Tighten mounting screws to 11 Nm (8 ft. lbs.) torque.
2. Install electrical connector.
3. Connect negative battery cable.