Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Component Tests and General Diagnostics

Input Signal Inspection Points






When Using the Scan Tool
1. Connect the scan tool to the data link connector.

CAUTION: Always turn the ignition switch off when connecting and disconnecting the scan tool.

2. If buzzer of the scan tool sounds once when a switch is operated (ON/OFF), the ECU input signal for that switch circuit system is normal.





When Using a Voltmeter
1. Use the special tool to connect a voltmeter between the ground terminal and the ETACS terminal of data link connector.
2. If the voltmeter indicator deflects once when a switch is operated (ON/OFF), the ECU input signal for that switch circuit system is normal.