Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Actuator Inspection

OPERATIONAL CHECK

NOTE: Before disconnecting the vacuum hose, mark it to ensure reconnection at the correct position.

Fuel Pressure Control Solenoid Valve Location:





1. Remove the vacuum hose (blue stripe on black) from the solenoid valve.
2. Disconnect the harness connector.

Fuel Pressure Control Solenoid Operational Test Hook-up:





3. Apply a negative pressure to the nipple to which the black vacuum hose has been connected and check air-tightness with and without the battery voltage applied to the solenoid valve terminal.

Battery The other nipple Normal state
voltage of solenoid valve


Not applied Open Negative pressure leak

Close with finger Negative pressure is
held

Applied Open Negative pressure is
held


COIL RESISTANCE CHECK

Fuel Pressure Control Solenoid Resistance Test Hook-up:





1. Measure the coil resistance with a circuit tester.

Standard Value 36 - 46 ohms @ 68°F (20°C)