Fuel Injector Resistance Test
Measurement of Resistance between Front Bank Terminals1. Disconnect the injector connector.
Checking Fuel Injector:
2. Measure the resistance between terminals.
Standard value: 13 - 16 ohms [at 20°C (68°F)]
3. Install the injector connector.
Measurement of Resistance between Rear Bank Terminals
Injector Intermediate Harness Connector:
1. Disconnect the injector intermediate connector.
2. Measure resistance between terminals.
Injector No. Measuring terminals Resistance
No. 2 1 - 2 13 - 16 ohms
No. 4 1 - 3 [At 20°C (68°F)]
No. 6 1 - 4