NS-7D Ignition System Primary Circuit
Complete No Start Test 7, Step C before proceeding.
1. With ignition coil negative wire disconnected, turn the ignition switch to the Off position.
2. Disconnect the 14-way connector from the SMEC, then connect an ohmmeter between terminal No. 12 of the connector, and ground.
3. If no continuity is shown, replace the SMEC.