Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

NS-10B Checking Injector No. 1 Circuit


Complete No Start Test 10, Step A before proceeding.

1. With diagnostic read-out tool connected to the engine test connector, the air intake plenum removed, all injectors disconnected, and system in ATM Test Mode 02, connect injector connector number 1 to injector number 1.
2. Leave connected for 10 seconds and listen for a click.
3. If injector clicks, proceed to Step H.
4. If injector does not click, proceed to Step C. Make sure ATM Test 02 has not timed out before proceeding to Step C.