Auxiliary Battery Positive Cable Replacement




Auxiliary Battery Positive Cable Replacement

Removal Procedure

1. Disconnect the negative battery. Refer to Battery Negative Cable Disconnection and Connection (Single Battery) (Service and Repair)Battery Negative Cable Disconnection and Connection (Dual Batteries) (Service and Repair)Battery Negative Cable Disconnection and Connection (Auxiliary Battery) (Service and Repair)




2. If equipped with dual generators,remove the mega fuse nut (1) on top of the auxiliary battery.




3. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (Single Battery) (Service and Repair)Battery Negative Cable Disconnection and Connection (Dual Batteries) (Service and Repair)Battery Negative Cable Disconnection and Connection (Auxiliary Battery) (Service and Repair).
4. Disconnect the generator battery jumper cable. Refer to Generator Battery Jumper Cable Replacement (Generator Battery Jumper Cable Replacement)
5. Loosen the auxiliary battery positive clamp nut (1) and remove the clamp from the battery post.
6. Remove the cable retainers (2) along the top of the fan shroud.




7. Remove the auxiliary battery positive harness clips (1) from the condensor hose and the transmission cooler hose.




8. Remove the mega fuse block nut (1) and the auxiliary battery positive cable terminal (2), from the mega fuse block.

Installation Procedure




1. If equipped with dual generators,connect the generator jumper cable (3) to the mega fuse holder with the nut (1) and tighten to 9 Nm (80 lb in)





Caution: Refer to Fastener Caution (Fastener Caution).

2. Install the auxiliary battery positive clamp to the battery post and tighten clamp nut (1) to 9 Nm (80 lb in)
3. Install the auxiliary battery positive cable retainers (2) along the cooling fan shroud.




4. Install the auxiliary battery positive cable clips (1) to the condensor hose and the transmission cooler hose.




5. Install the auxiliary battery positive cable terminal (2) to the mega fuse block and tighten the nut (1) to 9 Nm (80 lb in)
6. Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (Single Battery) (Service and Repair)Battery Negative Cable Disconnection and Connection (Dual Batteries) (Service and Repair)Battery Negative Cable Disconnection and Connection (Auxiliary Battery) (Service and Repair).