Fuel Injector Sight Shield Replacement
Fuel Injector Sight Shield Replacement
Removal Procedure
1. Remove the oil cap (1) and the oil filler tube (2).
2. Disconnect the exhaust gas recirculation (EGR) electrical connector (3).
3. Remove the injector sight shield from the studs.
4. If replacing the sight shield studs, remove the studs from the intake manifold.
Installation Procedure
Caution: Refer to Fastener Caution (Fastener Caution).
1. If the injector sight shield studs were removed, install the studs to the intake manifold and tighten to 10 Nm (89 lb in).
2. Install the injector sight shield to the studs.
3. Connect the EGR electrical connector (3).
4. Install the oil filler tube (2) and the oil cap (1).