Water Outlet Replacement
Water Outlet Replacement
Removal Procedure
1. Remove the radiator outlet hose. Refer to Radiator Outlet Hose Replacement (LY7) (Service and Repair)Radiator Outlet Hose Replacement (LNJ) (Service and Repair).
2. Remove the water outlet housing bolts (1).
3. Remove the housing.
4. Remove the water outlet housing O-ring seal (2).
5. Remove the water outlet housing seal (3). Discard seal.
Installation Procedure
1. Install a NEW water outlet housing seal (3).
2. Install a NEW water outlet housing O-ring seal (2).
Caution: Refer to Fastener Caution (Fastener Caution).
3. Install the water outlet housing bolts (1) and tighten to 10 Nm (89 lb in).
4. Install the radiator outlet hose. Refer to Radiator Outlet Hose Replacement (LY7) (Service and Repair)Radiator Outlet Hose Replacement (LNJ) (Service and Repair).