Recirculation Door Replacement (Heat Only)



Recirculation Door Replacement (Heat Only)

Removal Procedure

1. Remove the heater/vent module.




2. Disconnect the recirculation actuator electrical connection (1).




3. Remove the recirculation actuator mounting screws.




4. Remove the recirculation actuator.
5. Remove the recirculation door.

Installation Procedure




1. Install the recirculation door.
2. Install the recirculation actuator.





Notice: Refer to Fastener Notice.

3. Install the recirculation actuator mounting screws.

Tighten the screws to 1.9 N.m (17 lb in).




4. Connect the recirculation actuator electrical connection (1).
5. Install the heater/vent module.