Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Blower Motor Resistor - Auxiliary



BLOWER MOTOR RESISTOR REPLACEMENT - AUXILIARY

REMOVAL PROCEDURE
1. Remove the accessory panel from the left rear quarter trim.
2. Disconnect the auxiliary blower motor resistor electrical connector.




3. Remove the auxiliary blower motor resistor screws.
4. Remove the auxiliary blower motor resistor from the auxiliary HVAC module assembly.

INSTALLATION PROCEDURE




1. Install the auxiliary blower motor resistor to the auxiliary HVAC module assembly.
2. Install the auxiliary blower motor resistor screws.

Tighten the screws to 1.6 N.m (14 lb in).

NOTE: Refer to Fastener Notice.

3. Connect the auxiliary blower motor resistor electrical connector.
4. Install the accessory panel from the left rear quarter trim panel.