39. Camshaft and Bearings Clean and Inspect
Camshaft and Bearings Cleaning and Inspection
Tools Required
^ J7872 Magnetic Base Dial Indicator
1. Clean the camshaft in solvent.
2. Caution: Refer to Safety Glasses Caution in Service Precautions.
Dry the camshaft with compressed air.
3. Inspect the camshaft retainer plate for damage.
4. Inspect the camshaft for the following conditions:
^ Camshaft bearing journals (1) that are:
- Worn
- Scored
- Damaged
^ Worn camshaft lobes (2)
^ Damaged sprocket bolt threads (3)
^ Damaged sprocket pin (206)
5. Measure the camshaft journals with a micrometer.
6. Measure for excessive camshaft runout using J7872.
1. Mount the camshaft in a suitable fixture.
2. Use the J7872 in order to measure for a bent camshaft.
7. Replace the camshaft if runout exceeds specifications.
8. Inspect the camshaft bearings, 1-5, for wear or damage.