BLOWER MOTOR RESISTOR ASSEMBLY REPLACEMENT - AUXILIARY

REMOVAL PROCEDURE
1. Remove the accessory panel from the left rear quarter trim.
2. Disconnect the auxiliary blower motor resistor electrical connector.







3. Remove the auxiliary blower motor resistor screws.
4. Remove the auxiliary blower motor resistor from the auxiliary HVAC module assembly.




INSTALLATION PROCEDURE







1. Install the auxiliary blower motor resistor to the auxiliary HVAC module assembly.
2. Install the auxiliary blower motor resistor screws.

NOTE: Refer to Fastener Notice in Service Precautions.
Vehicle Damage Warnings

Tighten
Tighten the screws to.....1.6 N.m (14 lb in).

3. Connect the auxiliary blower motor resistor electrical connector.
4. Install the accessory panel from the left rear quarter trim panel.