Fuel Filler Door Innerlock Replacement
FUEL FILLER DOOR INTERLOCK REPLACEMENTREMOVAL PROCEDURE
1. Open the sliding door.
2. Remove the bolts from the fuel filler interlock bracket.
3. Slide the fuel filler interlock bracket toward the front of the vehicle.
4. Remove the fuel filler interlock from the body.
5. Disconnect the fuel filler interlock cable from the fuel filler interlock bracket.
INSTALLATION PROCEDURE
1. Connect the fuel filler interlock cable to the fuel filler interlock bracket.
2. Insert the fuel filler interlock into the proper hole in the body.
3. Slide the fuel filler interlock bracket toward the rear of the vehicle.
4. Install the bolts to the fuel filler interlock bracket.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the fuel filler door interlock bracket retaining bolts to 25 N.m (18 lb ft).
5. Close the sliding door.