California (RPO Code YF5, NE1, and VCL)
DTC P2228 CALIFORNIA (WITH RPO CODE YF5, NE1, AND VCL)CIRCUIT DESCRIPTION
The barometric pressure (BARO) sensor responds to changes in altitude and atmospheric conditions. This gives the engine control module (ECM) an indication of barometric pressure. The ECM uses this information to calculate fuel delivery. The BARO sensor has a 5-volt reference circuit, a low reference circuit, and a signal circuit. The ECM supplies 5 volts to the BARO sensor on a 5-volt reference circuit, and provides a ground on a low reference circuit. The BARO sensor provides a voltage signal to the ECM on a signal circuit relative to the pressure changes. The ECM monitors the BARO sensor signal for voltage outside of the normal range. If the ECM detects a BARO sensor signal voltage that is excessively low, this DTC will set.
CONDITIONS FOR RUNNING THE DTC
The engine is running.
CONDITIONS FOR SETTING THE DTC
The BARO is less than 44 kPa for 10 seconds.
ACTION TAKEN WHEN THE DTC SETS
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.
TEST DESCRIPTION
Steps 1-3:
Steps 4-7:
Steps 8-14:
The numbers below refer to the step numbers on the diagnostic table.
2. The BARO sensor 5-volt reference circuit is shared with other sensors. If DTC P0651 is set, this indicates that the 5-volt reference circuit is shorted to ground and should be diagnosed first. The short may be on another sensor 5-volt reference circuit.
4. If you cannot duplicate the DTC, the information included in the Freeze Frame/Failure Records data can aid in locating an intermittent condition.