Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

A/C - Blower Motor Noise on Second Speed Setting

Bulletin No.: 04-01-38-004A

Date: January 31, 2005

ADVANCE SERVICE INFORMATION RESOLUTION

Subject:
Blower Motor Noise on Second Speed Setting (Replace HVAC Control Module)

Models:
2003-2004 Chevrolet SSR

Supercede:

This bulletin is being revised to provide the correction and warranty information, which is now available for Advanced Service Information Bulletin Number 04-01-38-004. Please discard Corporate Bulletin Number 04-01-38-004 (Section 01 - HVAC).

Condition

Some customers may comment on a blower motor noise on the second speed setting.

Cause

This condition may be caused by the Heating, Ventilation and Air Conditioning (HVAC) control module using Pulse Width Modulation (PWM) to control the blower motor speed. PWM control of the blower motor only occurs on the second speed setting. For speeds 1, 3 and 4 the blower motor is controlled through the use of blower motor resistors. For high speed, setting 5, the HVAC control module provides a direct path to ground, without the use of resistors, to control the blower motor speed.

Correction

Technicians are to install a new HVAC Control Module, P/N 15230831, which uses a new PWM control method.

Dealer Action

Please contact all customers that were told they would be called when a repair became available.





Parts Information

Parts are currently available from GMSPO.

Warranty Information





For vehicles repaired under warranty, use the table.