Generator Replacement - Auxiliary
REMOVAL PROCEDURE1. Disconnect the negative battery cable.
2. Remove the drive belt.
3. Disconnect the auxiliary generator electrical connector (4).
4. Remove the auxiliary generator bolts.
5. Remove the auxiliary generator.
6. Remove the generator cable from the auxiliary generator, perform the following:
6.1. Slide the boot down revealing the terminal stud.
6.2. Remove the generator cable nut from the terminal stud.
6.3. Remove the generator cable.
7. If required, remove the auxiliary generator bracket bolt.
8. Remove the auxiliary generator bracket.
INSTALLATION PROCEDURE
1. If removed, install the auxiliary generator bracket.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the auxiliary generator bracket bolt.
Tighten
Tighten the auxiliary generator bracket bolt to 50 N.m (37 lb ft).
3. Install the generator cable to the auxiliary generator, perform the following:
3.1. Install the generator cable.
3.2. Install the generator cable nut to the terminal stud.
Tighten
Tighten the generator cable nut to 9 N.m (80 lb in).
3.3. Slide the boot over the terminal stud.
4. Install the auxiliary generator.
5. Install the auxiliary generator bolts.
Tighten
Tighten the auxiliary generator bolts to 50 N.m (37 lb ft).
6. Connect the auxiliary generator electrical connector (4).
7. Install the drive belt.
8. Connect the negative battery cable.