A/C Pressure Sensors
The A/C system is protected by two pressure switches. The 
A/C high pressure switch interrupts the A/C request signal when the A/C line pressure exceeds 
2896 kPa (420 psi). The 
A/C low pressure switch interrupts the A/C low pressure switch signal when the A/C line pressure falls below 
145-172 kPa (21- 25 psi). When the PCM sees an open in either signal, the A/C clutch relay control circuit is no longer grounded, thus shutting off the compressor. The low pressure switch will close when pressure reaches 
262 - 290 kPa (38-42 psi).