Air Conditioning (A/C) High Pressure Switch Replacement
Air Conditioning (A/C) High Pressure Switch Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
1. Remove the right wheelhouse panel. Refer to Wheelhouse Panel Replacement Service and Repair in Body Front End.
2. Disconnect the A/C high pressure switch electrical connector.
3. Remove the A/C high pressure switch (3) from the A/C hose.
Installation Procedure
1. Lightly coat the new O-ring seal using mineral base 525 viscosity refrigerant oil.
2. Install the new O-ring seal to the switch (3).
Notice: Refer to Fastener Notice in Cautions and Notices.
3. Install the A/C high pressure switch (3) to the A/C hose.
Tighten the switch to 6 Nm (53 lb in).
4. Connect the A/C high pressure switch electrical connector.
5. Leak test the fittings of the component using the J 39400-A .
6. Install the right wheelhouse panel. Refer to Wheelhouse Panel Replacement Service and Repair in Body Front End.