Floor Mode
When Floor is selected, air is delivered to the floor outlets. Vacuum is applied to the 
mode actuator through the Blue vacuum line, and to the defrost actuator through the Pink vacuum line. The mode actuator will retract, closing the Vent Door. The 
defroster actuator will retract, closing the Defroster Door and open the Heater Door through mechanical linkage.