Power Sliding Door - Opens With Transaxle Out of Park
Diagnostic Chart:
Schematic:
CIRCUIT DESCRIPTION
The rear side door actuator control module monitors the position of the transaxle shifter through the transaxle range switch. The rear side door actuator control module disables the sliding door operation when the transaxle is shifted out of the PARK position. The rear side door actuator control module sounds the PSD alarm for as long as the PSD open/close switch is pressed This alarm is to warn the driver that the PSD has been inhibited from opening.
If the transaxle is shifted out of the PARK position while the PSD is closing, the rear side door actuator control module sounds the PSD alarm. This alarm is to warn the driver that the sliding door is not fully closed.
The transaxle range switch sends a B+ signal to the rear side door actuator control module through circuit 275 when the transaxle is in the PARK position. When the transaxle is shifted out of the PARK position, the transaxle range switch removes the B+ signal to the rear side door actuator control module. This signal is removed through circuit 275.
DIAGNOSTIC AIDS
Inspect for the following conditions:
- A short to B+ in circuit 275
- An out-of-adjustment transaxle range switch
- A faulty transaxle range switch
^ An Intermittent failure may be difficult to detect and to accurately diagnose. Faulty electrical connections or wiring causes most Intermittent problems. When an Intermittent condition is suspected, inspect the suspected circuits for the following conditions:
- Improperly formed or damaged terminals
- Wire chafing
- Damaged connector bodies
^ Use a J 35616-A whenever a diagnostic procedure requests probing or inspecting a terminal. Using the J 35616-A ensures that no damage to the terminal will occur. Using the J 35616-A provides an estimate of whether the contact tension is sufficient.
TEST DESCRIPTION
The number(s) below refer to the step number(s) on the diagnostic table.
2. This step performs the Diagnostic Mode 2: Input Test.
3. This step determines if the transaxle range switch is faulty or if the PSD control module is faulty.
4. This step tests for a short to B+ in circuit 275.