Alternator: Service and Repair
REMOVAL PROCEDURECAUTION: Refer to Battery Disconnect Caution in Service Precautions.
1. Disconnect the negative battery cable
2. Remove the accessory drive belt.
3. Disconnect the electrical connections from the generator.
4. Remove the generator mounting bolts.
5. Remove the generator.
INSTALLATION PROCEDURE
1. Install the generator.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the generator mounting bolts.
Tighten
Tighten the bolts to 50 N.m (37 lb ft).
3. Connect the electrical connections to the generator.
Tighten
Tighten the B+ nut to 18 N.m (13 lb ft).
4. Install the accessory drive belt.
5. Connect the negative battery cable.
Tighten
Tighten to bolt to 17 N.m (13 lb ft).