Suspension Controls Circuit Description
Suspension Controls Circuit Description
Voltage is applied to the air suspension dump solenoid valve switch when the ignition switch is in RUN. When the switch is manually closed, voltage is then applied to the air suspension sump solenoid valve. Since this valve is permanently grounded at G405, the valve will be energized until the switch is manually opened. The air suspension dump indicator lamp receives a voltage signal from the switch when it is activated. The indicator lamp receives its ground through G101.