Daytime Running Lamp Relay: Service and Repair
Daytime Running Lamps (DRL) Relay Replacement
Removal Procedure
Caution: Refer to Battery Disconnect Caution in Cautions and Notices.
1. Disconnect the negative battery cable.
2. Remove the instrument panel cluster. Refer to Instrument Cluster Replacement Instrument Cluster Replacement in Instrument Panel, Gages and Console.
3. Remove the DRL relay from the relay block
Installation Procedure
1. Install the DRL relay into the relay block.
2. Install the instrument panel cluster. Refer to Instrument Cluster Replacement Instrument Cluster Replacement in Instrument Panel, Gages and Console.
3. Connect the negative battery cable.