Generator Brace Replacement (CS- 144)
REMOVAL PROCEDURE1. Remove the generator brace retainer bolts from the generator bracket.
2. Remove the generator brace retainer from the generator bracket.
3. Remove the generator brace.
INSTALLATION PROCEDURE
1. Install the generator brace.
2. Install the generator brace to the generator bracket.
NOTE: Refer to Fastener Notice in Cautions and Notices.
3. Install the generator brace retaining bolts to the generator brace and bracket.
Tighten
Tighten the generator brace retaining bolts to 50 N.m (37 lb ft).