Air Injection Control Valve: Service and Repair
REMOVAL PROCEDURECAUTION: Refer to Battery Disconnect Caution in Cautions and Notices.
1. Disconnect the negative battery cable.
2. Remove the inlet and outlet hoses from the air shut off valve.
3. Disconnect the vacuum hose from the air shut off valve.
4. Remove the air shut off valve retainer screw.
5. Remove the air shut off valve from the air pump.
INSTALLATION PROCEDURE
1. Install the air shut off valve on the air pump.
2. Install the air shut off valve retainer screw.
3. Connect the vacuum hose to the air shut off valve.
4. Install the inlet and outlet hoses on air shut off valve.