Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

P0449















Circuit Description
A voltage is supplied directly to the EVAP Vent valve solenoid. The PCM controls the solenoid by grounding the control circuit via an internal switch called a driver. The primary function of the driver is to supply the ground for the controlled component. Each driver has a fault line which the PCM monitors. The voltage of the control circuit should be low (near 0 volts) when the PCM commands a component ON. The voltage potential of the circuit should be high (near the battery voltage) when the PCM commands the control circuit to a component OFF. If the fault detection circuit senses a voltage other than what the PCM expects, the fault line status changes causing the DTC to set.

Conditions for Running the DTC
^ The engine speed is greater than 400 RPM.
^ The ignition voltage is between 6.0 volts and 18.0 volts.

Conditions for Setting the DTC
^ The PCM detects that the commanded state of the driver and the actual state of the control circuit do not match.
^ The conditions are present for a minimum of 5.0 seconds.

Action Taken When the DTC Sets
^ The PCM illuminates the Malfunction Indicator Lamp on the second consecutive ignition cycle that the diagnostic runs and fails.
^ The PCM records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the PCM stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the PCM records the operating conditions at the time of the failure. The PCM writes the conditions to the Freeze Frame and updates the Failure records.

Conditions for Clearing the MIL/DTC
^ The PCM turns the MIL OFF after three consecutive ignition cycles that the diagnostic runs and does not fail.
^ A last test failed (current DTC) clears when the diagnostic runs and does not fail.
^ A History DTC clears after forty consecutive warm-up cycles, if this or any other emission related diagnostic does not report any failures.
^ Use a scan tool in order to clear the MIL/DTC.

Diagnostic Aids

Important: Remove any debris from the PCM connector surfaces before servicing the PCM. Inspect the PCM connector gaskets when diagnosing/replacing the PCM. Ensure that the gaskets are installed correctly. The gaskets prevent water intrusion into the PCM.

Using Freeze Frame and/or Failure Records data may aid in locating an intermittent condition. If you cannot duplicate the DTC, the information included in the Freeze Frame and/or Failure Records data can aid in determining how many miles since the DTC set. The Fail Counter and Pass Counter can also aid determining how many ignition cycles the diagnostic reported a pass and/or a fail. Operate the vehicle within the same freeze frame conditions (RPM, load, vehicle speed, temperature etc.) that you observed. This will isolate when the DTC failed.
For an intermittent, refer to Symptoms. Symptom Related Diagnostic Procedures

Test Description
The numbers below refer to the step numbers on the diagnostic table.
2. Listen for an audible click when the solenoid operates. Be sure that both the ON and the OFF states are commanded. Repeat the commands as necessary.
3. This test can detect a partially shorted coil which would cause excessive current flow. Leaving the circuit energized for 2 minutes allows the coil to warm up. When warm the coil may open (amps drop to 0), or short (goes above 0.75 amp).
7. Momentarily probe the solenoid control circuit to ground. Listen for an audible click when the solenoid operates.
18. If no trouble is found in the control circuit or the connection at the PCM, the PCM may be faulty, however, this is an extremely unlikely failure.