P1154
Diagnostic Chart:
Diagnostic Chart:
Wiring Diagram:
CIRCUIT DESCRIPTION
Use this diagnostic test in conjunction with the HO2S (Bank 2, Sensor 1) slow response diagnostic test (P0153). The ratio of the response times that were calculated are compared to the calibrated limits. If the number of both the lean to rich transitions (switches) and the rich to lean transitions were both zero, then the ratios will set to 0. Otherwise, the ratio is calculated based on which average response time was greater. DTC P1154 is a type B DTC.
CONDITIONS FOR SETTING THE DTC
The following conditions sets the DTC:
^ HO2S voltage less than 300 mV is Lean.
^ HO2S voltage greater than 600 mV is Rich.
^ No Throttle Position (TP) sensor DTCs.
^ No EVAP DTCs.
^ No IAT sensor DTCs.
^ No MAP DTCs.
^ No ECT sensor DTCs.
^ No MAF DTCs.
^ No intrusive test in progress.
^ No device controls active.
^ System voltage is greater than or equal to 9 volts.
RESPONSE TEST ENABLE
^ Closed Loop Mode 0 not active.
^ Closed Loop.
^ DTCs P0151, P0152, P0154 and P0155 not active.
^ ECT is greater than 57°C Engine run time is greater than 75 seconds.
^ Air flow is greater than or equal to 15 g/s but less than or equal to 55 g/s.
^ Engine speed is greater than 1100 RPM but less than 3000 RPM.
^ Canister Purge Duty Cycle is greater than 0%.
^ Above conditions present for greater than 2 seconds.
ACTION TAKEN WHEN THE DTC SETS
The VCM turns on the Malfunction Indicator Lamp (MIL) after 2 consecutive test failures.
The VCM records the operating conditions at the time the diagnostic fails. The Freeze Frame and Failure Records store this information.
CONDITIONS FOR CLEARING THE MIL/DTC
The VCM turns the MIL off after 3 consecutive drive trips that the diagnostic runs and does not fail.
A Last Test Failed (current) DTC clears when the diagnostic runs and does not fail.
A History DTC clears after 40 consecutive warm-up cycles with no failures of any emission related diagnostic test.
The VCM battery voltage is interrupted.
The scan tool Clear Info function is used.
DIAGNOSTIC AIDS
Check the HO2S heater operation.
Never solder the HO2S wires. For proper wire and connector repairs, refer to Wiring Diagrams.
TEST DESCRIPTION
The numbers below refer to the step numbers in the diagnostic table.
2. This step check if the other possible causes of this DTC have already been diagnosed.
3. With the engine running warm, coolant at least 85°C (185 F) and at fast idle, the Oxygen sensor voltage should rapidly swing above 0.60 volts and below 0.30 volts.
5. This step checks to see if the HO2S voltage is swinging between rich and lean very slowly or not at all.
9. This step checks for causes of the HO2S failure. If the HO2S sensor is replaced without finding the cause of the contamination, the replacement sensor may become contaminated.