Blower Motor Relay: Service and Repair
Figure 52: Evaporator And Blower Assembly:
REMOVE OR DISCONNECT
1. Negative battery cable.
2. Electrical connectors, as necessary.
3. Screws (34).
4. Relay (42).
INSTALL OR CONNECT
1. Relay (42).
NOTICE: Refer to "Fasteners" under "Vehicle Damage Warnings."
2. Screws (34).
- Tighten screws (34) to 1.4 Nm (12 lbs. in.).
3. Electrical connectors, as necessary.
4. Negative battery cable.
- Check circuit operation.