Fuel Meter Cover Assembly
NOTE: The fuel meter cover assembly contains the fuel pressure regulator assembly. The regulator has been adjusted at the factory and should only be serviced as a complete assembly.Fuel Meter Cover (TBI):
REMOVE/DISCONNECT
- Electrical connectors to fuel injectors. (Squeeze plastic tabs and pull straight up).
- Long and short meter cover screw assemblies.
- Fuel meter cover assembly.
NOTE DO NOT immerse fuel meter cover (with pressure regulator) in cleaner, as damage to regulator and gasket could occur.
- Fuel meter outlet gasket and pressure regulator seal. Discard old gaskets and seal.
INSPECT
For dirt, foreign material and casting warpage.
INSTALL/CONNECT
- New pressure regulator seal, fuel meter outlet passage gasket, and cover gasket.
- Fuel meter cover assembly.
- Attaching screw assemblies, precoated with appropriate locking compound to threads. (Short screws are next to injectors.) Tighten screw assemblies to 3.0 Nm (27.0 lb-in).
- Electrical connectors to fuel injectors.
INSPECT
- Turn ignition switch to "ON" position for two seconds, then turn to "OFF" position for ten seconds. Again turn ignition switch to "ON" position and check for leaks around gaskets and fuel line couplings.