Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Low Speed Fan Circuit




CAUTION: Do not use a meter with an impedance of less than 10 Meg ohms.

1. Set the blower speed to LOW.
2. Insert the positive probe into terminal A (circuit 50) and the negative probe into terminal M (circuit 951). The voltage should read 11.5 to 12.0 volts. (This indicates that the controller is providing a ground to the LO speed fan relay.)
3. Move the negative probe to terminal L (circuit 963). The voltage should be 11.5 to 12.0 volts. (This indicates that the controller is properly providing a ground for the HI speed fan relay.)