Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Camshaft Position Actuator Solenoid Replacement - Bank 2 (Left Side) Exhaust



Camshaft Position Actuator Solenoid Replacement - Bank 2 (Left Side) Exhaust

Removal Procedure

1. Turn the ignition OFF.

Important: Do not disconnect the power steering fluid lines/hoses from the reservoir.

2. Remove the power steering fluid reservoir bolts and reposition the power steering fluid reservoir in order to provide access.




3. Remove the camshaft position (CMP) actuator valve electrical connector.




4. Remove the CMP actuator valve bolt.
5. Remove the CMP actuator valve.
6. Inspect the CMP actuator valve seal for damage. Replace the seal if necessary.

Installation Procedure

1. Inspect the CMP actuator valve seal for damage. Replace the seal if necessary.




2. Install the CMP actuator valve.

Notice: Refer to Fastener Notice.

3. Install the CMP actuator valve bolt.

Tighten the CMP actuator valve bolt to 10 N.m (89 lb in).




4. Install the CMP actuator valve electrical connector.
5. Install the power steering fluid reservoir.