Air Temperature Sensor - Lower Right
AIR TEMPERATURE SENSOR REPLACEMENT - LOWER RIGHT
REMOVAL PROCEDURE
1. Remove the HVAC module.
2. Disconnect the lower RH DTM sensor electrical connector.
IMPORTANT: Rotate the DTM sensor counter-clockwise to disengage the sensor from the lower duct.
3. Remove the lower RH DTM sensor from the HVAC module.
INSTALLATION PROCEDURE
1. Install the lower RH DTM sensor to the HVAC module.
IMPORTANT: Rotate the DTM sensor clockwise to engage the sensor to the lower duct.
2. Connect the lower RH DTM sensor electrical connector.