Heated Oxygen Sensor (HO2S) Replacement Bank 2 Sensor 2
HEATED OXYGEN SENSOR (HO2S) REPLACEMENT BANK 2 SENSOR 2
REMOVAL PROCEDURE
NOTE: Refer to Oxygen Sensor Notice in Service Precautions.
IMPORTANT:
- Remove oxygen sensors with the engine temperature above 48°C (120°F). Otherwise the oxygen sensors may be difficult to remove.
- A special anti-seize compound is used on the oxygen sensor threads. New service sensors should already have the compound applied to the threads. Coat the threads of a reused sensor with anti-seize compound P/N 5613695 or equivalent.
1. Raise and support the vehicle. Refer to Vehicle Lifting.
2. Disconnect the oxygen sensor electrical connector.
3. Remove the rear oxygen sensor from the exhaust manifold.
INSTALLATION PROCEDURE
1. Install the oxygen sensor in the exhaust manifold.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the HO2S sensor to 41 N.m (30 lb ft).
2. Connect the oxygen sensor electrical connector.
3. Lower the vehicle.