Air Temperature Sensor - Lower Left
AIR TEMPERATURE SENSOR REPLACEMENT - LOWER LEFT
REMOVAL PROCEDURE
1. Remove the HVAC module.
2. Disconnect the lower LH DTM sensor electrical connector.
3. Remove the lower LH DTM sensor from the HVAC module.
IMPORTANT: Rotate the DTM sensor counter-clockwise to disengage the sensor from the lower duct.
INSTALLATION PROCEDURE
1. Install the lower LH DTM sensor to the HVAC module.
IMPORTANT: Rotate the DTM sensor clockwise to engage the sensor to the lower duct.
2. Connect the lower LH DTM sensor electrical connector.
3. Install the HVAC module.