Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

P0341



DTC P0341

CIRCUIT DESCRIPTION
The powertrain control module (PCM) uses the camshaft position (CMP) sensor high resolution signal in order to determine the position of the valve train in relation to the engine cylinders. The PCM uses the CMP high resolution signal in order to sequence the ignition system and the fuel injectors.

The PCM supplies a 12-volt reference and a low reference to the CMP sensor. The CMP sensor returns a signal pulse in response to the reluctor track, located on the camshaft sprocket. The PCM runs the following 2 tests to diagnose the CMP sensor performance system:
- A Near Engine Start, CMP Fast Event Based test
- An After Engine Start, CMP Slow Event Based test

The Near Engine Start and the CMP Fast Event Based test runs first, upon or during, start-up. If the test fails, it will set DTC P0341. If the test passes, it will initiate the After Engine Start, CMP Slow Event Based test, and runs this test continuously. If the PCM detects an incorrect correlation between the CMP signal and the crankshaft position (CKP) signals, DTC P0341 will set.

DTC DESCRIPTOR
This diagnostic procedure supports the following DTC:
DTC P0341 Camshaft Position (CMP) Sensor Performance

CONDITIONS FOR RUNNING THE DTC

Near Engine Start, CMP Fast Event Based, Test
- The engine is cranking.
- DTC P0340 is not set.

After Engine Start, CMP Slow Event Based, Test
- The engine is running.
- DTCs P0335, P0340, P0385, and P1372 are not set.
- DTC P0341 runs continuously once the above conditions are met.

CONDITIONS FOR SETTING THE DTC

Near Engine Start, CMP Fast Event Based, Test
During cranking, the PCM detects an incorrect number of CMP sensor pulses in 2 revolutions of the crankshaft.

After Engine Start, CMP Slow Event Based, Test
The PCM detects an incorrect number of CMP sensor pulses in 2,000 revolutions of the crankshaft.

ACTION TAKEN WHEN THE DTC SETS
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.

DIAGNOSTIC AIDS
The following conditions may cause this DTC to set:
- Damage to the camshaft sprocket
- Incorrect sensor installation
- The sensor coming in contact with the camshaft sprocket
- Excessive air gap between the camshaft sprocket and the sensor
- A cracked or damaged sensor
- Foreign material passing between the sensor and the sprocket

If the condition is intermittent, refer to Intermittent Conditions. Intermittent Conditions

TEST

Steps 1 - 10: