General Information
Battery positive voltage (B+) is supplied at all times to the memory seat module (MSM) via CKT 2840 (ORN) from the MEM T&T Fuse in the rear fuse block. The MSM is supplied ground through CKT 550 (BLK) to G302. Battery positive voltage (B+) is supplied at all times to the MSM via CKT 3740 (RED) or (ORN) from the rear fuse block PWR SEAT circuit breaker, which is used by the MSM to control the seat motors. Each motor contains an electronic circuit breaker (PTC), which will reset only after voltage has been removed from the motor. Battery positive voltage (B+) is supplied at all times to the left seat switch via CKT 3740 (ORN) from the PWR SEAT circuit breaker in the rear fuse block. The left seat switch is supplied ground via CKT 550 (BLK) to G302.