Front Vertical

When the left seat switch is operated to move the front vertical up, battery positive voltage (B+) is applied via the front vertical up switch contacts and CKT 1518 (DK GRN) to the MSM. In response to this input, the MSM supplies battery positive voltage (B+) via CKT 286 (DK GRN) and ground via CKT 287 (DK BLU) to the left front vertical motor. The motor runs to drive the front of the seat up until the switch is released. When the left seat switch is operated to move the front vertical down, battery positive voltage (B+) is applied via the front vertical down switch contacts and CKT 1520 (DK BLU) to the MSM. In response to this input, the MSM supplies battery positive voltage (B+) via CKT 287 (DK BLU) and ground via CKT 286 (DK GRN) to the left front vertical motor. The motor runs to drive the front of the seat down until the switch is released. The MSM will also control the left front vertical motor during memory recall and easy exit functions.