EGR Valve Replacement (Replacement)
Removal Procedure1. Disconnect the electrical connector from the solenoid.
2. Remove the two mounting bolts (2) from the base of the EGR valve (1).
3. Remove the EGR Valve (1).
^ Inspect the EGR passages in the crossover water pump housing for deposits.
^ Clean the EGR passages as needed.
4. Clean the mounting surface for the EGR valve.
Installation Procedure
1. Install cleaned or replacement EGR valve (1) using a new gasket.
Notice: Refer to Fastener Notice in Service Precautions.
2. Install the two mounting bolts (2) at base of EGR valve.
Tighten the 2 mounting bolts to 24 N.m (18 lb ft).
3. Connect the electrical connector to EGR solenoid.