Recline
When the LH seat switch is operated to recline the seatback forward, battery positive voltage (B+) is applied via the recline forward switch contacts and CKT 276 (LT GRN) to the MSM. In response to this input, the MSM supplies battery positive voltage (B+) via CKT 276 (LT GRN) and ground via CKT 277 (LT BLU) to the LH recline motor. The motor runs to recline the seatback forward until the switch is released. When the LH seat switch is operated to recline the seatback back, battery positive voltage (B+) is applied via the recline back switch contacts and CKT 277 (LT BLU) to the MSM. In response to this input, the MSM supplies battery positive voltage (B+) via CKT 277 (LT BLU) and ground via CKT 276 (LT GRN) to the LH recline motor. The motor runs to recline the seatback back until the switch is released. The MSM will also control the LH recline motor during memory recall and easy exit functions.