Forward/Back
When the LH seat switch is operated to move the entire seat forward, battery positive voltage (B+) is applied via the entire seat forward switch contacts and CKT 1522 (TAN) to the MSM. In response to this input, the MSM supplies battery positive voltage (B+) via CKT 285 (TAN) and ground via CKT 284 (LT GRN) to the LH forward/back motor. The motor runs to drive the seat forward until the switch is released. When the LH seat switch is operated to move the entire 
seat back, battery positive voltage (B+) is applied via the entire seat back switch contacts and CKT 1523 (LT GRN) to the MSM. In response to this input, the MSM supplies battery positive voltage (B+) via CKT 284 (LT GRN) and ground via CKT 285 (TAN) to the LH forward/back motor. The motor runs to drive the seat back until the switch is released. The MSM will also control the LH forward/back motor during memory recall arid easy exit functions.