Continuously Variable Road Sensing Suspension (Cvrss)
Fig. 78 Code RS0061: RF Position Sensor Fault (Part 1 of 2).:
Fig. 78 Code RS0061: RF Position Sensor Fault (Part 2 of 2).:
DTC RS0061 RF CVRSS Position Sensor Fault (Part 1 Of 2):
TEST CONDITIONS:
The CVRSS control module monitors the CVRSS position sensor data for a sensor out-of- range condition. The signal is out-of-range if it is under voltage. (0.35 V) or over voltage (4.75 V).
FAULT CONDITIONS:
If the signal is out-of-range for more than 1 second, the fault is detected.
ACTION TAKEN:
Set code, turn on "SERVICE RIDE CONTROL" message, and enter a Speed Dependent Damping mode, in which all four dampers are concurrently driven by a fixed PWM duty cycle which changes (generally increases) as a function of vehicle speed.
DESCRIPTION:
The CVRSS control module monitors the CVRSS position sensor data for a sensor out-of-range condition. The signal is out-of-range if it is under voltage (0.35 V) or over voltage (4.75 V). If the signal is out-of-range for more than 1 second, the fault is detected.
NOTES ON FAULT TREE:
1. Refer to Intermittant.
TO DIAGNOSE THIS CONDITION:
^ Clear codes. Clearing Diagnostic Trouble Codes
^ Enter output cycling
^ Manipulate affected wiring
^ Shake and/or tap the sensor, and
^ Recheck for codes. Clearing Diagnostic Trouble Codes
2. A CVRSS position sensor input fault code may set due to the corresponding CVRSS position sensor supply over-current code being set. If this is the case, the over-current code must be diagnosed first.
3. Clear codes.